|
Diablo Analytical, Inc. Home Phone: 925-609-1150
|
Laboratory Gas Chromatography and GC-MS Solutions
Summary of Solutions
Custom GC and MS MethodsGC Column SelectionGC column selection is critical for successful applications. The right column can result in a robust method, while the wrong column can produce variable or sample-dependant results. Column choice must also be matched to sample and analyte type, injection conditions, detector requirements and system GC resolution. Method development requires an experienced person to choose the best column for an application. Inlet Selection and External Sampling DevicesSplit and splitless injection is used for most GC applications. However, other inlets can provide critical advantages for samples that can not be analyzed with a split inlet. Modern on-column injectors and PTV inlets are reliable and automated. Other inlets are also used for special applications: APEX, thermal desorption, pyrolysis, headspace, purge and trap, etc. Diablo can help determine the best inlet configuration to use for your application.
Valve Sampling and Switching Solutions
Main Oven Sampling and Switching Valves
Multi-port Sample-stream SelectionDiablo incorporates VICI (Valco) valve and control technology into an enclosure designed for manufacturing or lab environments. Diablo's MPValve software provides computer control of the stream-selection system. The system is designed to operate in a fully automated mode with the Agilent ChemStation or other data system, or it can be operated under manual control.
Auxiliary Heated ValvesDiablo Analytical, Inc. can locate automated sampling valves in several locations on the Agilent 6890 GC. Serviceability and temperature requirements are important considerations.
Sampling System InertnessGC results, particularly in trace analysis, can be compromised due to analyte loss in the sampling system. The sampling system must minimize adsorption or condensation loss. Special materials of construction and sampling system design can help reduce this problem. Diablo has a great deal of experience with the design and specification of sampling systems for trace analysis. Custom Automation and Software SolutionsThe programmers at Diablo Analytical have been creating custom software solutions for chemical measurement applications for more than a decade. We combine Agilent GC and MS ChemStation macros with Visual Basic (or VBA) applications to solve specific data processing problems. A few example projects that we have completed are listed below. Simplified User Interface for Agilent GC and LC ChemStationsOne-button control of an Agilent GC or LC ChemStation Sequence. The Simplified User Interface (SUI) greatly simplifies the operation of the ChemStation. See our Simplified User Interface product page for more information. We have developed custom versions of the SUI software to address specific customer requirements. Please contact Diablo Analytical for more information. Multi-position Valve Control SoftwareDiablo's MPValve software can be used to automate one or more VICI (Valco) multi-position valves for applications like stream and column selection. MPValve has been used to add multi-position valve control to a number of different chromatographic data systems. Standard Compound Chromatogram DatabaseDiablo developed a set of ChemStation macros that allow "standard" chromatograms to be retrieved and compared automatically to a sample chromatogram in a post run report. This automated database saved the client a significant amount of time over the previous manual comparison procedure they had been using. Custom Simulated Distillation ApplicationsDiablo developed a set of custom Simulated Distillation applications to perform D2887 and D3710 analyses. These SimDis applications included extensive QA/QC evaluations of data quality and custom report formats that were specified by the client. Gas System MonitorWhen analyzing toxic or pyrophoric specialty gases, it is critical that the gas sampling system be operating properly before performing an analysis. Diablo wrote a custom application that monitored several sampling system pressure and flow sensors, and would prevent the Agilent ChemStation from starting an analysis if the sampling system wasn't ready. Sequence Summary and Data Transfer to Microsoft ExcelDiablo has written several different sequence summary macros for the Agilent ChemStation. These macros typically create comma-delimited text files containing a client-specified summary of the results for all the runs in a sequence. These macros have also been configured to "poke" sequence summary results into Microsoft Excel. Automated Data Transfer to LabViewLabView is a commonly-used process control, data acquisition and data analysis program developed by National Instruments. Diablo has written Agilent ChemStation macros that automatically transfer the results of a ChemStation run to LabView for real-time process control applications. Automated Data Transfer to LIMSDiablo has written several applications that automate the transfer of analytical results into Laboratory Information Managements Systems (LIMS). Our clients often use custom LIMS systems that require custom data transfer approaches. Quotation and Purchasing InformationPlease contact Diablo Analytical to discuss your specific application requirements and to receive a project quotation. Diablo Analytical, Inc. 1110 Burnett Ave, Suite CP.O. Box 5889 Concord, CA 94524 Phone: (925) 609-1150 Fax: (925) 609-9360 E-Mail: info@diabloanalytical.com |
|
Copyright 1996-2008, Diablo Analytical, Inc., All Rights Reserved
|